The cleaning

00:00:05.605 --> 00:00:08.675
test is performed
on all pediatric specimens to aid

00:00:08.675 --> 00:00:13.346
in the early diagnosis of inborn errors
of metabolism, such as galactose anemia.

00:00:14.013 --> 00:00:17.951
Each facility will have its own protocol
regarding the performance of this test.

00:00:18.384 --> 00:00:19.652
The performance of the clinical

00:00:19.652 --> 00:00:23.156
test will be demonstrated using positive
and negative control specimens.

00:00:23.590 --> 00:00:27.527
Positive identification of a specimen
must be maintained through the complete

00:00:27.527 --> 00:00:29.295
testing process.

00:00:29.295 --> 00:00:32.098
Supplies needed to perform
this test include

00:00:32.098 --> 00:00:35.001
paper towels, a test tube rack,

00:00:35.001 --> 00:00:38.004
clean dry test tubes, tweezers,

00:00:38.271 --> 00:00:41.407
a permanent marker, disposable pipettes,

00:00:42.308 --> 00:00:45.879
laboratory
grade water clinic, test tablets,

00:00:46.279 --> 00:00:50.250
and the manufacturer's color chart
using a permanent marker

00:00:50.316 --> 00:00:55.722
label one test tube for each specimen
to be tested thoroughly mixed the specimen

00:00:55.722 --> 00:00:58.958
by gently inverting the container
a minimum of eight times.

00:00:59.692 --> 00:01:01.160
Remove the cap from the specimen

00:01:01.160 --> 00:01:04.297
container and place its specimen
side up onto the benchtop.

00:01:05.131 --> 00:01:07.333
Using a disposable pipette, dispense

00:01:07.333 --> 00:01:10.670
five drops of the urine specimen
into the appropriate test tube.

00:01:11.170 --> 00:01:13.907
Dispose of the pipette
into a bio hazardous waste

00:01:13.907 --> 00:01:16.910
receptacle using a disposable pipette.

00:01:17.043 --> 00:01:20.446
Dispense ten drops of laboratory
grade water into the test tube

00:01:20.446 --> 00:01:22.582
containing the urine specimen.

00:01:22.582 --> 00:01:26.019
Dispose of the pipette
into a bio hazardous waste receptacle.

00:01:26.719 --> 00:01:30.890
Using clean, dry tweezers,
retrieve one and test tablet per specimen

00:01:30.890 --> 00:01:34.661
from the bottle and gently
drop it into the liquid in the test tube.

00:01:35.061 --> 00:01:38.531
Be careful as the addition of the tablet
to the liquid causes

00:01:38.531 --> 00:01:43.136
an exothermic reaction in the test tube,
and generates very high temperatures.

00:01:43.603 --> 00:01:46.472
Note that the specimen boils
within the tube.

00:01:46.472 --> 00:01:48.374
If this reaction is not observed,

00:01:48.374 --> 00:01:51.377
the clinical test tablets
may not be working properly.

00:01:51.811 --> 00:01:55.448
Clinical test tablets are sensitive
to light, heat, and moisture,

00:01:55.782 --> 00:01:58.618
so the bottle needs to be capped
and sealed immediately

00:01:58.618 --> 00:02:01.554
after removing a tablet
and when not in use.

00:02:01.554 --> 00:02:05.591
Also, do not touch the tablets
with anything but the tweezers.

00:02:06.225 --> 00:02:10.329
Recap the specimen watch
while the boiling reaction takes place.

00:02:10.830 --> 00:02:13.900
Be careful not to disturb the test tube
during the reaction.

00:02:14.434 --> 00:02:18.271
Once the boiling has ceased, start
a timer for 15 seconds.

00:02:18.638 --> 00:02:22.275
Do not disturb the tube during this 15
second incubation

00:02:22.275 --> 00:02:25.344
time after the 15 second incubation.

00:02:25.411 --> 00:02:28.448
Gently shake the test tube to mix
the contents of the tube.

00:02:29.081 --> 00:02:32.852
Compare the color of the solution
against the manufacturer's color chart,

00:02:33.119 --> 00:02:36.422
while ignoring any sediment that may have
formed at the bottom of the tube.

00:02:36.756 --> 00:02:39.759
Record the results
as indicated on the color chart.

00:02:40.026 --> 00:02:43.830
Discard the reaction test tube
into a bio hazardous waste receptacle.